TRACe<1|2>:IQ:AVERage:COUNt
0 .. 32767
This command defines the number of I/Q data sets that are to serve as a basis for averaging.
Example:
TRAC:IQ ON
'Switches on acquisition of I/Q data.
TRAC:IQ:SYNC ON
'Switches on synchronization of the aquision of I/Q measurement data with the
trigger time.
TRAC:IQ:SET NORM,10MHz,32MHz,EXT,POS,0,2048
'Reads 2048 I/Q values from the moment of triggering.
'Filter type: NORMAL (analogue)
'RBW: 10 MHz
'Sample Rate: 32 MHz
'Trigger: external
'Slope: positive
TRAC:IQ:AVER ON
'
Enables averaging of the I/Q measurement data
TRAC:IQ:AVER:COUN 10
'
Selects averaging over 10 data sets
TRAC:IQ:DATA?
'Starts the measurement and reads out the averaged data.
Characteristics: *RST value:
0
SCPI: conform
Mode:
A
This command is available from firmware version 1.32 or higher.
TRACe<1|2>:IQ:AVERage[:STATe]
ON|OFF
The command enables averaging of the recorded I/Q data provided that I/Q data acquisition was
previously enabled with TRAC:IQ ON and the sampling rate was set to 32 MHz.
Averaging is not supported at sampling rates <> 32 MHz or for a trigger offset < 0.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...