Operating Manual 1164.4556.12 - 06
6.147
R&S FSP
Remote Control – Description of Commands
SENSe Subsystem
Example:
"BAND:TYPE NORM"
Characteristics:
*RST value: NORMal
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo
1 Hz to 10 MHz
This command defines the instrument's video bandwidth.
Bandwidths from 1 Hz to 10 MHz in 1, 3, 10
steps are available. The command is not available if FFT filtering is switched on and the set bandwidth
is
≤
30 kHz or if the quasipeak detector is switched on.
Example:
"BAND:VID 10kHz"
Characteristics:
*RST value: - (AUTO is set to ON)
SCPI: conform
Mode:
A
[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:AUTO
ON | OFF
This command either automatically couples the instrument's video bandwidth to the resolution
bandwidth or cancels the coupling.
The ratio video bandwidth/resolution bandwidth can be modified with the command
[SENSe<1|2>:
]BANDwidth:VIDeo:RATio
.
Example:
"BAND:VID:AUTO OFF"
Characteristics:
*RST value: ON
SCPI: conform
Mode:
A
[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:RATio
0.01 to 1000
This command defines the ratio video bandwidth (Hz) / resolution bandwidth (Hz).The ratio to be
entered is reciprocal to the ratio RBW/VBW used in manual operation.
Example:
"BAND:VID:RAT 3"
'Sets the coupling of video bandwidth to video bandwidth = 3*resolution bandwidth
Characteristics:
*RST value: 3
SCPI: conform
Mode:
A
[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:TYPE
LINear | LOGarithmic
This command selects the psition of the video filter in the signal path, provided that the resolution
bandwidth is
≤
100 kHz:
• If LINear is selected, the video filter is connected ahead of the logarithmic amplifier (default)
• If LOGarithmic is selected, the video filter follows the logarithmic amplifier
The essential difference between the two modes is the transient response at falling signal edges:
If LINear is selected, the measurement with logarithmic level scaling yields a much "flatter" falling edge
than LOGarithmic. This behavior is due to the conversion of linear power into logarithmic level. If the
linear power is halved, the level decreases by only 3 dB.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...