SENSe Subsystem
[SENSe<1|2>:]LIST:POWer:RESult?
This command queries the result of a previous list measurement as configured and initiated with
SENSe:LIST:POWer[:SEQuence]
. The measured results are output in a list of floating point values
separated by commas. The unit of the results depends on the setting made with the
CALC:UNIT
command.
This command may be used to obtain measurement results in an asynchronous way, using the service
request mechanism for synchronization with the end of the measurement.
If no measurement results are available, the command will return a query error.
Example:
'Configuration of the status reporting system for the generation of an SRQ
on operation complete
*ESE 1
*SRE 32
'Configuring and starting the measurement
"SENSe:LIST:POWer
935.2MHz,-20dBm,10dB,OFF,NORM,1MHz,3MHz,434us,0,
935.4MHz,-20dBm,10dB,10dB,NORM,30kHz,100kHz,434us,0,
935.6MHz,-20dBm,10dB,20dB,NORM,30kHz,100kHz,434us,0;
*OPC"
'Further actions of the control computer during measurement
to
'Response to service request
On SRQ:
SENSe:LIST:POWer:RESult?
Characteristics:
*RST value: --
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]LIST:POWer[:SEQuence]
<analyzer freq>,<ref level>,<rf att>,<el att>, <filter type>,
<rbw>, <vbw>, <meas time>,<trigger level>
This command configures the list of settings (max. 100 entries) for the multiple power measurement
and starts a measurement sequence. When synchronizing the command with *OPC, a service request
is generated as soon as all frequency points are processed and the defined number of individual
measurements is reached.
To reduce the setting time, all indicated parameters are set up simultaneously at each test point.
The query form of the command processes the list and immediately returns the list of results. The
number of results per test point depends on the setting of the "
SENSe:LIST:POWer:SET
" command.
The following parameters are the settings for an individual frequency point. They
are repeated for every other frequency point.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...