CALCulate<1|2>:MARKer<1...4>:FUNCtion:
STRack:THReshold
-330 to +30 dBm
new function for
R&S FSP
R&S
FSP
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
STRack:TRACe
1 to 3
new function for
R&S FSP
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
STRack[:STATe]
ON | OFF
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:AOFF
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:AVERage
ON | OFF
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MAXimum: AVERage:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MAXimum: PHOLd:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MAXimum: RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MAXimum [:STATe]
ON | OFF
not available for
R&S FSP
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MEAN: AVERage:RESult?
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MEAN:PHOLd:RESult?
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MEAN:RESult?
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MEAN[:STATe]
ON | OFF
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MIDDle: AVERage:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MIDDle: PHOLd:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MIDDle: RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MIDDle [:STATe]
ON | OFF
not available for
R&S FSP
R&S
FSP
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MODE
ABSolute | RELative
new function for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MPEak: AVERage:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MPEak: PHOLd:RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MPEak: RESult?
not available for
R&S FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:MPEak [:STATe]
ON | OFF
not available for
R&S FSP
R&S
FSP
FSE
CALCulate<1|2>:MARKer<1...4>:FUNCtion:
SUMMary:PHOLd
ON | OFF
Devices
Command
(Sheet 11 of 47)
Parameter
Notes
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...