Operating Manual 1164.4556.12 - 06
6.305
R&S FSP
Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
FSET
INPut<1|2>:PRESelection:COUPling:LOW:
FREQuency
10Hz to 5MHz
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:COUPling:LOW:SET
'name of preselector set
for low RBW'
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:COUPling:MID:SET
'name of preselector set
for medium RBW'
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:FILTer:HPASS[:
FREQuency]
100Hz to 5MHz
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:FILTer:LPASS[:
FREQuency]
20KHz to 40MHz
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:FILTer[:STATe]
ON | OFF
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:SET
NARRow | NORMal |
WIDE
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection:USET[:SELect]
'name of user defined
preselector set'
not available for
R&S FSP
FSET
INPut<1|2>:PRESelection[:STATe]
ON | OFF
not available for
R&S FSP
FSET
INPut<1|2>:TYPE
RF | BALanced
not available for
R&S FSP
ESIB
INPut<1|2>:TYPE
INPUT1 | INPUT2
not available for
R&S FSP
FSE
INPut<1|2>:UPORt<1|2>:STATe
ON | OFF
not available for
R&S FSP
FSE
INPut<1|2>:UPORt<1|2>[:VALue]?
not available for
R&S FSP
ESIB
INPut2:COUPling
AC | DC
not available for
R&S FSP
INSTrument:COUPle
NONE | RLEVel | CF_B |
CF_A
available coupling
modes between Screen
A and Screen B have
been changed between
FSE and R&S FSP
FSE
INSTrument:COUPle
NONE | MODE | X | Y |
CONTrol | XY |
XCONtrol | YCONtrol |
ALL
Available coupling
modes between screen
A and screen B have
been changed between
FSE and R&S FSP
INSTrument<1|2>:NSELect
1
currently only parameter
value 1 available
ESIB
INSTrument<1|2>:NSELect
1 to 3 | 6
4 parameter values are
available
FSE/
FSIQ
INSTrument<1|2>:NSELect
1 to 5
5 parameter values are
available
FSET
INSTrument<1|2>:NSELect
1 | 2 | 6
3 parameter values are
available
INSTrument<1|2>[:SELect]
SANalyzer Currently
only
SANalyzer available
Devices
Command
(Sheet 26 of 47)
Parameter
Notes
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...