15 - 76
15.6 Device Range that Can Be Set
*1
MELSERVO-JE is equivalent to MELSERVO-J4.
However, they have differences in the parameter function.
For using the MELSERVO-JE series, refer to the following.
➠
MELSERVO-JE Series Servo Amplifier Instruction Manual
(14) Alarm (extended for MELSERVO-J4-*A)
AL200
Alarm number from Alarm History most recent alarm
―
AL201
Alarm number from Alarm History first alarm in past
―
AL202
Alarm number from Alarm History second alarm in past
―
AL203
Alarm number from Alarm History third alarm in past
―
AL204
Alarm number from Alarm History fourth alarm in past
―
AL205
Alarm number from Alarm History fifth alarm in past
―
AL210
Alarm occurrence time in alarm history most recent alarm
―
AL211
Alarm occurrence time in alarm history first alarm in past
―
AL212
Alarm occurrence time in alarm history second alarm in past
―
AL213
Alarm occurrence time in alarm history third alarm in past
―
AL214
Alarm occurrence time in alarm history fourth alarm in past
―
AL215
Alarm occurrence time in alarm history fifth alarm in past
―
AL230
Detailed alarm from Alarm History most recent alarm
―
AL231
Detailed alarm from Alarm History first alarm in past
―
AL232
Detailed alarm from Alarm History second alarm in past
―
AL233
Detailed alarm from Alarm History third alarm in past
―
AL234
Detailed alarm from Alarm History fourth alarm in past
―
AL235
Detailed alarm from Alarm History fifth alarm in past
―
Device name
Item
Symbol
ALM0
Current alarm number
―
ALM1
*1
Detailed data of current alarms
―
ALM11
Servo status when alarm occurs Cumulative feedback pulses
―
ALM12
Servo status when alarm occurs Servo motor speed
―
ALM13
Servo status when alarm occurs Droop pulses
―
ALM14
Servo status when alarm occurs cumulative command pulses
―
ALM15
Servo status when alarm occurs command pulse frequency
―
ALM16
Servo status when alarm occurs analog speed command voltage/limit voltage
―
ALM17
Servo status when alarm occurs analog torque command voltage/limit voltage
―
ALM18
Servo status when alarm occurs regenerative load ratio
―
ALM19
Servo status when alarm occurs effective load ratio
―
ALM20
Servo status when alarm occurs peak load ratio
―
ALM21
Servo status when alarm occurs Instantaneous torque
―
ALM22
Servo states when alarm occurs Within onerevolution position(1 pulse unit)
―
ALM23
Servo status when alarm occurs ABS counter
―
ALM24
Servo status when alarm occurs load inertia moment ratio
―
ALM25
Servo status when alarm occurs Bus voltage
―
ALM26 to 42
For manufacturer setting
―
ALM43
Servo states when alarm occurs Internal temperature of encoder
―
ALM44
Servo states when alarm occurs Setting time
―
ALM45
Servo states when alarm occurs Oscillation detection frequency
―
ALM46
Servo states when alarm occurs Number of tough drives
―
ALM47 to 50
For manufacturer setting
―
ALM51
Servo states when alarm occurs Unit power consumption 1 (incremwnt of 1 W)
―
ALM52
Servo states when alarm occurs Unit total power consumption 1 (incremwnt of 1 Wh)
―
Device name
Item
Symbol
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......