15 - 74
15.6 Device Range that Can Be Set
*1
For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after
setting the parameter data.
*2
MELSERVO-JE is equivalent to MELSERVO-J4.
However, they have differences in the parameter function.
For using the MELSERVO-JE series, refer to the following.
➠
MELSERVO-JE Series Servo Amplifier Instruction Manual
(9) Extension setting 2 parameter
(10) Extension setting 3 parameter
(11) Linear servo motor/DD motor setting parameter
PD28, PD1028
Output device selection 6
*DO6
PD29, PD1029
Input filter setting
*DIF
PD30, PD1030
Function selection D-1
*DOP1
PD31, PD1031
For manufacturer setting
―
PD32, PD1032
Function selection D-3
*DOP3
PD33, PD1033
For manufacturer setting
―
PD34, PD1034
Function selection D-5
*DOP5
PD35 to 48, PD1035 to 1048
For manufacturer setting
―
Device name
Item
Symbol
PE1 to 40, PE1000 to 1040
For manufacturer setting
―
PE41, PE1041
Function selection E-3
EOP3
PE42 to 64, PE1042 to 1064
For manufacturer setting
―
Device name
Item
Symbol
PF1 to 8, PF1001 to 1008
For manufacturer setting
―
PF9, PF1009
*1
Function selection F-5
*FOP5
PF10 to 14, PF1010 to 1014
For manufacturer setting
―
PF15, PF1015
*1
Electronic dynamic brake operating time
DBT
PF16 to 20, PF1016 to 1020
For manufacturer setting
―
PF21, PF1021
Drive recorder switching time setting
DRT
PF22, PF1022
For manufacturer setting
―
PF23, PF1023
Vibration tough drive - Oscillation detection level
OSCL1
PF24, PF1024
Vibration tough drive function selection
OSCL2
PF25, PF1025
Instantaneous power failure tough drive - Detection time
CVAT
PF26 to 30, PF1026 to 1030
For manufacturer setting
―
PF31, PF1031
Machine diagnosis function - Friction judgement speed
FRIC
PF32 to 48, PF1032 to 1048
For manufacturer setting
―
Device name
*2
Item
Symbol
*1
PL1, PL1001
Linear servo motor/DD motor function selection 1
*LIT1
PL2, PL1002
Linear encoder resolution - Numerator
*LIM
PL3, PL1003
Linear encoder resolution - Denominator
*LID
PL4, PL1004
Linear servo motor/DD motor function selection 2
*LIT2
PL5, PL1005
Position deviation error detection level
LB1
PL6, PL1006
Speed deviation error detection level
LB2
PL7, PL1007
Torque/thrust deviation error detection level
LB3
PL8, PL1008
Linear servo motor/DD motor function selection 3
*LIT3
PL9, PL1009
Magnetic pole detection voltage level
LPWM
PL10 to PL16, PL1010 to PL1016
For manufacturer setting
―
PL17, PL1017
Magnetic pole detection - Minute position detection method - Function selection
LTSTS
PL18, PL1018
Magnetic pole detection - Minute position detection method - Identification signal
amplitude
IDLV
Device name
Item
Symbol
*1
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......