The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may not
be monitored.
15.6.1
When directly connecting the GOT to a servo amplifier
■1.
Device settings
*1
Refer to the following.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Information
Displays the device type and setting range which are selected in [Device].
Network
Set the monitor target of the set device.
All
Select this item when writing data to all servo amplifiers connected.
During a monitoring, the servo amplifier of Station No. 0 is monitored.
When inputting data by Numerical Input, the data is written to all servo amplifiers connected during
inputting; the servo amplifier of Station No. 0 is monitored during other than inputting (displaying).
Selection
Select this item when monitoring the servo amplifier of the Station No. specified.
After selecting, set station numbers of servo amplifiers in the following range.
0 to 31:
The servo amplifier of the Station No. specified will be monitored.
100 to 115:
Specify the Station No. of the servo amplifier to be monitored with a GOT data register (GD).
*1
Switch to the
device define
dialog
Clicking the button displays the dialog box indicating the correspondence between the GOT virtual device for a servo amplifier
and the definition of servo amplifier.
If selecting an item on the displayed dialog box, remember that the servo amplifier definition is displayed in the text box below.
Station No.
GOT data register (GD)
Setting range
100
GD10
0 to 31
(If setting a value out of the range above,
a timeout error occurs.)
101
GD11
:
:
114
GD24
115
GD25
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......