12.4 PLC Side Setting
12 - 23
CC-Link
C
O
NN
ECTION (INTELLIGE
NT DEVICE ST
A
T
ION)
12
12.4.3
Connecting to CC-Link module (MELSEC iQ-R Series) with Ver.1/Ver.2
compatibles mixed
This section describes the setting of the GOT and CC-Link module (MELSEC iQ-R Series) with Ver.1/Ver.2 compatibles
mixed in the following system configuration.
POINT
POINT
POINT
CC-Link module (MELSEC iQ-R Series)
For details of the CC-Link module (MELSEC iQ-R Series), refer to the following manual.
➠
Manuals of MELSEC iQ-R Series
■1.
System configuration
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0".
■2.
Module parameter setting of GX Works3
(1) [Module parameter] of GX Works3
(a)
Module parameter
: Necessary : As necessary : Not necessary
*1
Adjust the settings with GOT settings.
Item
Set value
Setting necessity at GOT connection
Station type
Master station
Mode
Remote net (Ver.2 mode)
Station No.
0 (fixed)
Transmission speed
*1
156kbps
Parameter setting
Parameter
<CC-Link module>
*1
Type
: Master station
Station No.
: Station No.0
Mode Setting
: Remote net (Ver.2 mode)
All connect count
: 2
Transmission speed
: 156kbps
<GOT(Ver.1 compatible)>
(Use the default value for
settings other than the following.)
Station type
: Intelligent
device station
Station No.
: Station No.1
Number of
stations occupied
Exclusive station 1
:
:
Transmission speed
156kbps
(Use the default value for settings other than the following.)
<GOT(Ver.2 compatible)>
(Use the default value for
settings other than the following.)
Station type
: Intelligent
device station
Station No.
: Station No.2
Number of
stations occupied
Exclusive
station 1
:
Expanded cyclic
setting
Single
:
Transmission speed :
156kbps
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......