5 - 64
5.4 PLC Side Setting
■1.
System configuration (for Q series)
*1
The Ethernet module is mounted on the base unit slot 0.
The Start I/O No. of the Ethernet module is set to "0".
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of the Ethernet module is set to "70".
■2.
[Network parameter] of GX Developer
(1) Network parameter
Item
Set value
Setting necessity at GOT
connection
Network type
Ethernet (fixed)
Starting I/O No.
*1
0000H
Network No.
*2
1
Group No.
0 (fixed)
Station No.
*3
2
Mode
Online (fixed)
Operation setting
Refer to (2)
<GOT> (The settings other than the
following are set to the default)
*1
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.3.18
Port No.
: 5001
Communication format : UDP (fixed)
Network No.
: 1
PLC No.
: 2
IP address
: 192.168.3.19
Port No.
: 5001
Communication format
: UDP(fixed)
<Ethernet module> (The settings other than the
following are set to the default)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......