15 - 56
15.6 Device Range that Can Be Set
(6) Extension setting parameter
*1
For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after
setting the parameter data.
Device name
Item
Symbo
l*1
PC1, PC1001
Acceleration time constant
STA
PC2, PC1002
Deceleration time constant
STB
PC3, PC1003
S-pattern acceleration/deceleration time constant
STC
PC4, PC1004
Torque command time constant
TQC
PC5, PC1005
Internal speed command1/limit1
SC1
PC6, PC1006
Internal speed command2/limit2
SC2
PC7, PC1007
Internal speed command3/limit3
SC3
PC8, PC1008
Internal speed command4/limit4
SC4
PC9, PC1009
Internal speed command5/limit5
SC5
PC10, PC1010
Internal speed command6/limit6
SC6
PC11, PC1011
Internal speed command7/limit7
SC7
PC12, PC1012
Analog speed command maximum speed/limit maximum speed
VCM
PC13, PC1013
Analog torque command maximum output
TLC
PC14, PC1014
Analog monitor 1 output
MOD1
PC15, PC1015
Analog monitor 2 output
MOD2
PC16, PC1016
Electromagnetic brake sequence output
MBR
PC17, PC1017
Zero speed
ZSP
PC18, PC1018
Alarm history clear
*BPS
PC19, PC1019
Encoder output pulse selection
*ENRS
PC20, PC1020
Station number setting
*SNO
PC21, PC1021
Communication function selection
*SOP
PC22, PC1022
Function selection C-1
*COP1
PC23, PC1023
Function selection C-2
*COP2
PC24, PC1024
Function selection C-3
*COP3
PC25, PC1025
For manufacturer setting
―
PC26, PC1026
Function selection C-5
*COP5
PC27 to PC29, PC1027 to PC1029
For manufacturer setting
―
PC30, PC1030
Acceleration time constant 2
STA2
PC31, PC1031
Deceleration time constant 2
STB2
PC32, PC1032
Command pulse multiplying factor numerator 2
CMX2
PC33, PC1033
Command pulse multiplying factor numerator 3
CMX3
PC34, PC1034
Command pulse multiplying factor numerator 4
CMX4
PC35, PC1035
Internal torque limit 2
TL2
PC36, PC1036
Status display selection
*DMD
PC37, PC1037
Analog speed command offset/limit offset
VCO
PC38, PC1038
Analog torque command offset/limit offset
TPO
PC39, PC1039
Analog monitor 1 offset
MO1
PC40, PC1040
Analog monitor 2 offset
MO2
PC41 to PC50, PC1041 to PC1050
For manufacturer setting
―
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......