5.2 System Configuration
5 - 15
5
E
T
H
E
RNET CONNEC
T
ION
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
*2
A straight cable is available.
When connecting CPU and GOT directly with Ethernet cable, remember that the by cross cable is available.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of Built-in Ethernet port QCPU, refer to the following manual.
➠
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
*5
Select [QnUD(P)V/QnUDEH] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
➠
*6
For the system configuration of Built-in Ethernet port LCPU, refer to the following manual.
➠
MELSEC-L CPU Module User's Manual (Built-In Ethernet Function)
*7
Select [LCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
➠
*8
Select [RCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
➠
*9
For the system configuration of Built-in Ethernet port RCPU, refer to the following manual.
➠
MELSEC iQ-R CPU Module User's Manual (Built-In Ethernet Function)
*10
Select [FX5CPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
➠
*11
For the system configuration of MELSEC iQ-F series, refer to the following manual.
➠
MELSEC iQ-F User's Manual
*12
By the controller type of the C Controller module (Q Series) and an operation mode, It's different in number of connectable GOTs.
*13
GT25-W, GT2505-V does not support the option device.
Controller Type
Operation mode
Number of connectable GOTs
Q12DCCPU-V
standard monitor mode
1
Expansion mode
16
Q24DHCCPU-V/VG/LS
-
16
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......