14 - 42
14.2 System Configuration
■12.
Connecting a sensorless servo (FREQROL-E700EX series)
Make the communication settings of the sensorless servo (FREQROL-E700EX series).
Be sure to perform the inverter reset after updating each parameter.
(1) Communication port and corresponding parameters
(2) Communication settings of sensorless servo
Set the following parameters using the PU (operation panel or parameter unit).
Do not change these parameters, even though they can be monitored from the GOT. If they are changed,
communication with the GOT is disabled.
*1
Setting items are parameter names described in the manual of sensorless servo (FREQROL-E700EX series).
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change the parameters on the inverter to correspond with the GOT settings.
*3
Sensorless servo (FREQROL-E700EX series) default values (No need to change)
GOT connection destination
Parameters corresponding to inverter
PU connector
Pr.79, Pr.117 to Pr.124, Pr.340, Pr.342, Pr.549
FR-E7TR
(RS-485 terminal block)
Setting item
*1
Parameter No.
Set value
Contents of setting
PU communication station number
Pr.117
0 to 31
➠
PU communication speed
*2
Pr.118
192
*3
19200bps
PU communication stop bit length
*2
Pr.119
10
Data length: 7bit
Stop bit length: 1bit
PU communication parity check
*2
Pr.120
1
Odd
Number of PU communication retries
Pr.121
9999
The inverter will not come to an
alarm stop.
PU communication check time interval
Pr.122
9999
Communication check suspension
PU communication wait time setting
Pr.123
0
0ms
PU communication CR/LF selection
Pr.124
1
*3
With CR, without LF
Protocol selection
Pr.549
0
*3
Mitsubishi Electric inverter protocol
Operation mode selection
Pr.79
0
*3
PU operation mode
Communication startup mode selection
Pr.340
1
Network operation mode.
Communication EEPROM write selection
Pr.342
0
*3
Written to RAM and EEPROM
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......