17.5 CNC Side Settings
17 - 21
17
CNC CONNECTION
(2) Contents of setting
*1
Set as necessary.
*2
Set the station No. not to overlap with that of other units.
For details of the parameter setting, refer to the following.
➠
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
No.
Switch name
Settings
1)
Condition setting
switch
Set the operation condition.
No.
Description
Switch status
Setting validity
OFF
ON
Master
station
(Standby
master
station)
Local
station
(Standby
master
station)
SW1
Station type
*1
Master station/local station
Standby master station
(Valid)
(Valid)
SW2
Not used
Always OFF
-
-
SW3
Not used
Always OFF
-
-
SW4
Data link error
station input data
status
*1
Clear
Hold
valid
valid
SW4
Number of
occupied
stations
*1
OFF
1
Station
OFF
2
Station
ON
3
Station
ON
4
Station
Invalid
valid
SW5
OFF
ON
ON
OFF
SW7
Not used
Always OFF
-
-
SW8
Not used
Always OFF
-
-
2)
Mode setting
switch
This switch sets the unit operation status.
No.
Name
Description
Settability
Master
station
Local
station
0
Online
*1
Automatic online return provided when data link is enabled
Yes
Yes
1
Link with remote I/O net mode
Yes
No
2
Offline
*1
Data link offline state
Yes
Yes
3
Line test 1
*1
Line test 1 in offline state
Yes
No
4
Line test 2
*1
Line test 2 in offline state
Yes
No
5
Parameter
confirmation
test
*1
Checks the parameter details
Yes
No
6
Hardware test
*1
Test Expansion unit (FCU6-HR865)
Yes
Yes
7 to F
Not usable
3)
Transmission
speed setting
switch
This switch sets the unit transmission speed.
No.
Description
0
156Kbps
*1
1
625Kbps
*1
2
2.5Mbps
*1
3
5Mbps
*1
4
10Mbps
*1
5 to F
Not usable
4)
Setting switch of
station No.
This switch sets the unit station No.
*1*2
(Setting range)
Master station: 00
Local station: 01 to 64
Standby master station: 01 to 64
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......