2.3 MELSEC iQ-F
2 - 41
2
DE
VICE RANGE THA
T
CAN BE SE
T
• PB, PC, PE: 1 to 64
• PD, PF, PL: 1 to 48
Use the following devices to write data to the E2PROM of a servo amplifier.
• PA: 1001 to 1032
• PB, PC, PE: 1001 to 1064
• PD, PF, PL: 1001 to 1048
*7
For the servo amplifier, if a real number is written to the device, only the integer portion of the number is stored in the device.
If the data type of the servo amplifier device is set to [Real], the value after the writing may differ from the one before the writing.
In addition, the monitoring performance may slow down.
Therefore, select one of the following items for the data type of the device.
• [Signed BIN16]
• [Unsigned BIN16]
• [Signed BIN32]
• [Unsigned BIN 32]
When you use the value of the servo amplifier device, remember that only the integer portion of the value is stored in the device.
To display a real number on the numerical display or numerical input object, set [Format] to [Real] and select [Adjust Decimal
Point Range] in the object setting.
*8
Only the own station can be monitored. An error will occur if another station is monitored.
*9
Monitoring or writing is not possible in the continuous device designation mode by GT21.
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......