15 - 60
15.6 Device Range that Can Be Set
■8.
MELSERVO-J3-*T
*1
Use 1 to 50 of PA, PB, PC, PD, and PO when the GOT writes data to RAM of the servo amplifier.
Use 1001 to 1050 of PA, PB, PC, PD, and PO when the GOT write data to E
2
PROM of the servo amplifier.
Use PA,PB,PC,PD,PO 1001 to 1050 when reading parameters to the servo amplifier RAM.
*2
When the GOT writes data to point tables, use 1001 to 1255 of POS, SPD, ACT, DCT, DWL, AUX, and MCD (E
2
PROM area).
Even if the GOT writes a value to POS, SPD, ACT, DCT, DWL, AUX, or MCD (1 to 255) in the RAM area, the value is not
reflected.
*3
MCD cannot be used as a real number.
*4
Only reading is possible.
*5
The GOT cannot read or write data from/to consecutive devices.
*6
Only reading is possible for DI0 to DI4.
Device name
*5
Setting range
Device No.
representation
Bit device
Servo amplifier request (SP)
SP0 to SP6
Decimal
Operation mode selection (OM)
OM0 to OM5
Instruction demand (for test operation) (TMB)
TMB1 to TMB6
Word device
Basic setting parameter (PA)
*1
PA1 to PA19
PA1001 to PA1019
Decimal
Gain filter parameter (PB)
*1
PB1 to PB45
PB1001 to PB1045
Extension setting parameter (PC)
*1
PC1 to PC50
PC1001 to PC1050
I/O setting parameter (PD)
*1
PD1 to PD30
PD1001 to PD1030
Option unit parameter (PO)
*1
PO1 to PO35
PO1001 to PO1035
Status display (ST)
*4
ST0 to ST17
Alarm (AL)
*4
AL0 to AL1
AL11 to AL28
AL200 to AL205
AL210 to AL215
AL230 to AL235
External input (DI)
*6
DI0 to DI7
External output (DO)
*4
DO0 to DO4
Point table (position) (POS)
*2
POS1 to POS255
POS1001 to POS1255
Point table (speed) (SPD)
*2
SPD1 to SPD255
SPD1001 to SPD1255
Point table (acceleration time constant) (ACT)
*2
ACT1 to ACT255
ACT1001 to ACT1255
Point table (deceleration time constant) (DCT)
*2
DCT1 to DCT255
DCT1001 to DCT1255
Point table (dwell) (DWL)
*2
DWL1 to DWL255
DWL1001 to DWL1255
Point table (auxiliary function) (AUX)
*2
AUX1 to AUX255
AUX1001 to AUX1255
Point table (M code) (MCD)
*2*3
MCD1 to MCD255
MCD1001 to MCD1255
Double word device
Input signal for test operation (for test operation) (TM0)
TMI0 to TMI2
Forced output of signal pin (for test operation) (TMO)
TMO0 to TMO1
Set data (for test operation) (TMD)
TMD0 to TMD1
TMD3
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......