15.6 Device Range that Can Be Set
15 - 75
SER
V
O
AMPLIFIER CONNECTION
15
*1
For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after
setting the parameter data.
*2
These devices cannot be used for MELSERVO-JE
(12) Status display
(13) Alarm (compatible with MELSERVO-J3-*A)
PL19 to PL48, PL1019 to PL1048
For manufacturer setting
―
Device name
Item
Symbol
ST0
Comulative feedback pulse
―
ST1
Servo motor speed
―
ST2
Droop pulse
―
ST3
Cumulative command pulse
―
ST4
Command pulse frequency
―
ST5
Analog speed command voltage/limit voltage
―
ST6
Analog torque command voltage/limit voltage
―
ST7
Regenerative load ratio
―
ST8
Effetive load ratio
―
ST9
Peak load ratio
―
ST10
Instantaneous torque
―
ST11
Within one-revolution position(1 pulse unit)
―
ST12
ABS counter
―
ST13
Load inertia moment ratio
―
ST14
Bus voltage
―
ST15 to 31
For manufacturer setting
―
ST32
Internal temperature of encoder
―
ST33
Setting time
―
ST34
Oscillation detection frequency
―
ST35
Number of tough drives
―
ST36 to 39
For manufacturer setting
―
ST40
Unit power consumption 1 (incremwnt of 1 W)
―
ST41
Unit total power consumption 1 (incremwnt of 1 Wh)
―
Device name
Item
Symbol
AL0
Current alarm number
―
AL1
*1
Detailed data of current alarms
―
AL11
Servo status when alarm occurs Cumulative feedback pulses
―
AL12
Servo status when alarm occurs Servo motor speed
―
AL13
Servo status when alarm occurs Droop pulses
―
AL14
Servo status when alarm occurs cumulative command pulses
―
AL15
Servo status when alarm occurs command pulse frequency
―
AL16
Servo status when alarm occurs analog speed command voltage/limit voltage
―
AL17
Servo status when alarm occurs analog torque command voltage/limit voltage
―
AL18
Servo status when alarm occurs regenerative load ratio
―
AL19
Servo status when alarm occurs effective load ratio
―
AL20
Servo status when alarm occurs peak load ratio
―
AL21
Servo status when alarm occurs Instantaneous torque
―
AL22
Servo states when alarm occurs Within onerevolution position(1 pulse unit)
―
AL23
Servo status when alarm occurs ABS counter
―
AL24
Servo status when alarm occurs load inertia moment ratio
―
AL25
Servo status when alarm occurs Bus voltage
―
Device name
*2
Item
Symbol
*1
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......