ip domain-lookup
Enable dynamic host-name to address resolution (that is, DNS).
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
p domain-lookup
To disable DNS lookup, use the
no ip domain-lookup
command.
Defaults
Disabled.
Command Modes
CONFIGURATION
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 8.1.1.0
Introduced on the E-Series ExaScale.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
Usage
Information
To fully enable DNS, also specify one or more domain name servers with the
ip name-
server
command.
FTOS does not support sending DNS queries over a VLAN. DNS queries are sent out all other
interfaces, including the Management port.
To view current bindings, use the
show hosts
command.
Related
Commands
ip name-server
– specifies a DNS server.
show hosts
– Views the current bindings.
ip domain-name
Configure one domain name for the switch.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
ip domain-name
name
To remove the domain name, use the
no ip domain-name
command.
Parameters
name
Enter one domain name to be used to complete unqualified names
(that is, incomplete domain names that cannot be resolved).
Defaults
Not configured.
Command Modes
CONFIGURATION
852
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...