Related
Commands
dot1x authentication (Interface)
– enables dot1x on an interface.
dot1x authentication (Interface)
Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
dot1x authentication
To disable dot1x on an interface, use the
no dot1x authentication
command.
Defaults
Disabled.
Command Modes
INTERFACE
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.6.1.0
Introduced on the C-Series and S-Series.
Version 7.4.1.0
Introduced on the E-Series.
Related
Commands
dot1x authentication (Configuration)
– enables dot1x globally.
dot1x auth-fail-vlan
Configure an authentication failure VLAN for users and devices that fail 802.1X authentication.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
dot1x auth-fail-vlan
vlan-id
[max-attempts
number
]
To delete the authentication failure VLAN, use the
no dot1x auth-fail-vlan
vlan-
id
[max-attempts
number
]
command.
Parameters
vlan-id
Enter the VLAN Identifier. The range is 1 to 4094.
max-attempts
number
(OPTIONAL) Enter the keywords
max-attempts
followed number
of attempts desired before authentication fails. The range is 1 to 5.
The default is 3.
Defaults
3 attempts
Command Modes
CONFIGURATION (conf-if-interface-slot/port)
Command History
Version 8.3.7.0
Introduced on the S4810.
Version 7.6.1.0
Introduced on the C-Series, S-Series, and E-Series.
Usage
Information
If the host responds to 802.1X with an incorrect login/password, the login fails. The switch
attempts to authenticate again until the maximum attempts configured is reached. If the
1434
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...