private-vlan mode
Set PVLAN mode of the selected VLAN to community, isolated, or primary.
C-Series, S-Series, Z-Series, S4810
Syntax
[no] private-vlan mode {community | isolated | primary}
To remove the PVLAN configuration, use the
no private-vlan mode {community |
isolated | primary}
command syntax.
Parameters
community
Enter the keyword
community
to set the VLAN as a community
VLAN.
isolated
Enter the keyword
isolated
to configure the VLAN as an isolated
VLAN.
primary
Enter the keyword
primary
to configure the VLAN as a primary
VLAN.
Defaults
none
Command Modes
INTERFACE VLAN
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.8.1.0
Introduced on the C-Series and S-Series.
Usage
Information
The VLAN:
•
can be in only one mode, either
community
,
isolated
, or
primary
.
•
mode ode to
community
or
isolated
even before associating it to a primary
VLAN. This secondary VLAN continues to work normally as a normal VLAN even
though it is not associated to a primary VLAN. (A syslog message indicates this.)
•
must not have a port in it when VLAN mode is being set.
Only ports (and port channels) configured as promiscuous, host, or PVLAN trunk ports (as
described above) can be added to the PVLAN. No other regular ports can be added to the
PVLAN.
After using this command to configure a VLAN as a primary VLAN, use the
private-vlan
mapping secondary-vlan
command to map secondary VLANs to this VLAN.
Related
Commands
private-vlan mapping secondary-vlan
– maps secondary VLANs to the selected primary VLAN.
show interfaces private-vlan
– displays the type and status of the PVLAN interfaces.
show vlan private-vlan
– displays the PVLANs and/or interfaces that are part of a PVLAN.
show vlan private-vlan mapping
– displays the primary-secondary VLAN mapping.
switchport mode private-vlan
– sets PVLAN mode of the selected port.
1279
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...