linecard (4-port 40G line card)
Pre-configure an empty slot in an E-Series ExaScale switch for a 4-port 40 GigabitEthernet (40GE) line card or
reconfigure a slot in which you have hot-swapped a 4-port 40GE line card.
E-Series ExaScale Only
Syntax
linecard
slot-number card-type
{linerate | oversubscribed}
active-ports port-set0
port-number
[
port-number
] port-set1
port-number
[
port-number
]
Parameters
slot-number
Enter the slot number in which you will use the line card. The range is
0 - 13 on the E1200i and 0 - 5 on the E600i.
card-type
Enter the line card ID. Valid values are:
•
EX04PH: Configures the slot for a 6-port 40GE line card with
10M CAM (LC-EH-40GE-4P).
•
EX04PJ: Configures the slot for a 6-port 40GE line card with
40M CAM (LC-EJ-40GE-4P).
linerate
Configure two ports on the line card to transmit data at full line rate
(40 Gbps).
oversubscribed
Configure four ports on the line card for oversubscribed data
transmission.
active-ports
Enable the active ports for the specified mode (linerate or
oversubscribed).
port-set0
port-
number
[
port-
number
]
Enter the port number(s) used to specify the active ports on port pipe
0. Port-number range: 0 - 2.
On port pipe 0, 0 - 2 corresponds to ports 0, 1, and 2 on the line card. If
you configure linerate mode, enter one port number for port pipe 0.
If you configure oversubscribed mode, enter two port numbers
(separated by a space).
port-set1
port-
number
[
port-
number
]
Enter the port number(s) used to specify the active ports on port pipe
1. Port-number range: 0 - 2.
On port pipe 1, 0 - 2 corresponds to ports 3, 4, and 5 on the line card. If
you configure linerate mode, enter one port number for port pipe 1.
If you configure oversubscribed mode, enter two port numbers
(separated by a space).
Defaults
When you insert a 4-port 40GE line card in an ExaScale slot, the line card is set to operate in
oversubscribed mode with active ports 1 and 2 on port pipe 0 (portset0 1 2) and active ports 0
and 1 on port pipe 1 (portset1 0 1).
Command Modes
CONFIGURATION
Command History
Version 8.5.1.0
Introduced on the E-Series ExaScale E600i and E1200i.
131
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...