clear isis
Restart the IS-IS process. All IS-IS data is cleared.
E-Series, S4810
Syntax
clear isis [
tag
] {* | database | traffic}
Parameters
tag
(Optional) Enter an alphanumeric string to specify the IS-IS routing
tag area.
*
Enter the keyword
*
to clear all IS-IS information and restart the IS-IS
process. This command removes IS-IS neighbor information and IS-IS
LSP database information and the full SPF calculation is done.
database
Clears IS-IS LSP database information.
traffic
Clears IS-IS counters.
Command Modes
EXEC Privilege
Command History
Version 8.3.12.0
Introduced on the S4810.
clns host
Define a name-to-network service mapping point (NSAP) that you use with commands that require NSAPs and system
IDs.
E-Series, S4810
Syntax
clns host
name nsap
Parameters
name
Enter an alphanumeric string to identify the name-to-NSAP mapping.
nsap
Enter a specific NSAP address that is associated with the name
parameter.
Defaults
Not configured.
Command Modes
ROUTER ISIS
Command History
Version 8.3.12.0
Introduced on the S4810.
Usage
Information
Use this command to configure a shortcut name that you can use instead of entering a long
string of numbers associated with an NSAP address.
Related
Commands
hostname dynamic
– enables dynamic learning of host names from routers in the domain and
allows the routers to advertise the host names in LSPs.
970
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...