Command Modes
CONFIGURATION
Command History
Version 8.2.1.0
Introduced on the E-Series ExaScale.
Version 7.6.1.0
Introduced on the C-Series.
Version 7.4.1.0
Introduced on the E-Series.
Related
Commands
show bfd neighbors
– displays the BFD neighbor information on all interfaces or a specified
interface.
isis bfd all-neighbors
Enable BFD on all IS-IS neighbors discovered on an interface.
E-Series, Z-Series, S4810
Syntax
isis bfd all-neighbors [disable | [interval
interval
min_rx
min_rx
multiplier
value
role {active | passive}]]
To remove all BFD sessions with IS-IS neighbors discovered on this interface, use the
no
isis bfd all-neighbors [disable | [interval
interval
min_rx
min_rx
multiplier
value
role {active | passive}]]
command.
Parameters
disable
(OPTIONAL) Enter the keyword
disable
to disable BFD on this
interface.
interval
milliseconds
(OPTIONAL) Enter the keywords
interval
to specify non-default
BFD session parameters beginning with the transmission interval. The
range is 50 to 1000. The default is 100.
min_rx
milliseconds
Enter the keywords
min_rx
to specify the minimum rate at which
the local system would like to receive control packets from the
remote system. The range is 50 to 1000. The default is 100.
multiplier
value
Enter the keywords
multiplier
to specify the number of packets
that must be missed in order to declare a session down. The range is
3 to 50. The default is 3.
role [active |
passive]
Enter the role that the local system assumes:
•
Active
—The active system initiates the BFD session. Both
systems can be active for the same session.
•
Passive
—The passive system does not initiate a session. It
only responds to a request for session initialization from the
active system.
The default is Active.
Defaults
See Parameters
Command Modes
INTERFACE
343
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...