Field
Description
Operational status
(local port)
Port state for current operational ETS configuration:
•
Init
: Local ETS configuration parameters were exchanged
with the peer.
•
Recommend
: Remote ETS configuration parameters were
received from the peer.
•
Internally propagated
: ETS configuration
parameters were received from the configuration source.
ETS DCBX Oper
status
Operational status of the ETS configuration on the local port: match
or mismatch.
State Machine Type
Type of state machine used for DCBX exchanges of ETS parameters:
Feature — for legacy DCBX versions; Asymmetric — for an IEEE
version.
Conf TLV Tx Status
Status of ETS Configuration TLV advertisements: enabled or
disabled.
ETS TLV Statistic:
Input Conf TLV pkts
Number of ETS Configuration TLVs received.
ETS TLV Statistic:
Output Conf TLV pkts
Number of ETS Configuration TLVs transmitted.
ETS TLV Statistic:
Error Conf TLV pkts
Number of ETS Error Configuration TLVs received.
Example
(Summary)
FTOS(conf-qos-policy-out-ets)#show interface te 0/3 ets de
Interface TenGigabitEthernet 0/3
Max Supported TC Groups is 4
Number of Traffic Classes is 8
Admin mode is on
Admin Parameters :
------------------
Admin is enabled
TC-grp Priority# Bandwidth TSA
------------------------------------------------
0 - -
1 0,1,2 100% ETS
2 3 0 % SP
3 4,5,6,7 0 % SP
4 - -
5 - -
6 - -
7 - -
Remote Parameters :
-------------------
Remote is disabled
Local Parameters :
------------------
Local is enabled
618
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...