![Dell Force10 S4810P Скачать руководство пользователя страница 144](http://html.mh-extra.com/html/dell/force10-s4810p/force10-s4810p_reference-manual_86004144.webp)
Command History
Version 8.1.1.0
Introduced on the E-Series ExaScale.
Version 7.5.1.0
Introduced on the C-Series.
E-Series
Original command.
Example
FTOS#FTOS#show chassis brief
Chassis Type : E1200
Chassis Mode : TeraScale
Chassis Epoch : 3.2 micro-seconds
-- Line cards --
Slot Status NxtBoot ReqTyp CurTyp Version Ports
----------------------------------------------------
0 not present
1 not present
2 not present
3 not present
4 not present
5 not present
6 not present
7 not present
8 not present
9 not present
10 not present
11 online online E48PF E48PF 6.1.1.0 48
12 not present E48PF
13 not present E48PF
-- Route Processor Modules --
Slot Status NxtBoot Version
------------------------------------------------------
0 active online 6.1.1.0
1 not present
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-------------------------------------------------------
0 active
1 active
2 active
3 active
4 active
5 active
6 active
7 active
8 active
-- Power Entry Modules --
Bay Status
-------------------------------------------------------
0 up
1 up
-- Fan Status --
Tray Status Temp Volt Speed PEM0 PEM1 Fan1 Fan2 Fan3
-------------------------------------------------------
0 up < 50C 12-16V low/2100-2700 RPM up up up up up
1 up < 50C 12-16V low/2100-2700 RPM up up up up up
2 up < 50C 12-16V low/2100-2700 RPM up up up up up
3 up < 50C 12-16V low/2100-2700 RPM up up up up up
Related
Commands
show linecard
– view the line card status.
show rpm
– view the RPM status.
show sfm
– view the SFM status.
144
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...