21
High Availability (HA)
High availability (HA) in the Dell Force10 operating software (FTOS) is configuration synchronization to minimize
recovery time in the event of a route processor module (RPM) failure. The feature is available on the C-Series, E-Series,
S-Series, and S4810 platforms. High availability is supported on the S-Series S4810 with FTOS version 8.3.12.0 and on the
E-Series ExaScale with FTOS version 8.1.1.0 and later.
FTOS on the E-Series supports RPM 1 + 1 redundancy. The Primary RPM performs all routing and control operations,
while the Secondary RPM is online and monitoring the Primary RPM.
In general, a protocol is defined as “hitless” in the context of an RPM failure/failover and not failures of a line card, SFM,
or power module. A protocol is defined as hitless if an RPM failover has no impact on the protocol.
You must specifically enable some protocols for HA. Some protocols are only hitless if related protocols are also
enabled as hitless (for example, the
redundancy protocol
command).
patch flash://RUNTIME_PATCH_DIR
Insert an In-Service Modular Hot-Fix patch.
E-Series, S4810
Syntax
patch flash://RUNTIME_PATCH_DIR/
patch-filename
To remove the patch, use the
no patch flash://RUNTIME_PATCH_DIR/patch-
filename
command.
Defaults
none
Command Modes
CONFIGURATION
Command History
Version 8.3.12.0
Introduced on the S4810.
Version 8.2.1.0
Introduced.
Usage
Information
The patch filename includes the FTOS version, the platform, the CPU, and the process it affects
(
FTOS-platform-cpu-process-patchversion.rtp
). For example, a patch labeled
“7.8.1.0-EH-rp2-l2mgr-1.rtp” identifies that this patch applies to FTOS version 7.8.1.0 - E-Series
platform, for RP2, addressing the layer 2 management process, and this patch is the first
version of this patch.
There is no need to reload or reboot the system when you insert the patch. The In-Service
Modular patch replaces the existing process code. After installation is complete, the system
executes the patch code as though it was always there.
Related
Commands
show patch
– displays the system patches loaded with the
in-service modular hot
fix
command.
725
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...