To delete a setting, use the
no set metric-type
command.
Parameters
internal
Enter the keyword
internal
to assign the Interior Gateway
Protocol metric of the next hop as the route’s BGP MULTI_EXIT_DES
(MED) value.
external
Enter the keyword
external
to assign the IS-IS external metric.
type-1
Enter the keyword
type-1
to assign the OSPF Type 1 metric.
type-2
Enter the keyword
type-2
to assign the OSPF Type 2 metric.
Defaults
Not configured.
Command Modes
ROUTE-MAP
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 8.3.1.0
Implemented the keyword
internal
.
Version 8.1.1.0
Introduced on the E-Series ExaScale.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
pre-Version
6.1.1.0
Introduced on the E-Series.
Related
Commands
set automatic-tag
– computes the tag value of the route.
set level
– specifies the OSPF area for route redistribution.
set metric
– specifies the metric value assigned to redistributed routes.
set tag
– specifies the tag assigned to redistributed routes.
set next-hop
Configure a filter to specify an IP address as the next hop.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
set next-hop
ip-address
To delete the setting, use the
no set next-hop
ip-address
command.
Parameters
ip-address
Specify an IP address in dotted decimal format.
Defaults
Not configured.
Command Modes
ROUTE-MAP
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
321
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...