Related
Commands
•
show running-config uplink-state-group
– displays the current configuration of one or
more uplink-state groups.
•
uplink-state-group
– create an uplink-state group and enables the tracking of upstream
links.
uplink-state-group
Create an uplink-state group and enable the tracking of upstream links on a switch/ router.
S-Series (S50 only), S4810
Syntax
uplink-state-group
group-id
To delete an uplink-state group, enter the
no uplink-state-group group-id
command.
Parameters
group-id
Enter the ID number of an uplink-state group. The range is 1 to 16.
Defaults
none
Command Modes
CONFIGURATION
Command History
Version 8.3.12.0
Introduced on the S4810.
Version 8.4.2.3
Introduced on the S-Series S50.
Usage
Information
After you enter the command, enter Uplink-State-Group Configuration mode to assign
upstream and downstream interfaces to the group.
An uplink-state group is considered to be operationally up if at least one upstream interface in
the group is in the Link-Up state.
An uplink-state group is considered to be operationally down if no upstream interfaces in the
group are in the Link-Up state. No uplink-state tracking is performed when a group is disabled
or in an operationally down state.
To disable upstream-link tracking without deleting the uplink-state group, use the
no enable
command in uplink-state-group configuration mode.
Example
FTOS(conf)#uplink-state-group 16
FTOS(conf)#
02:23:17: %RPM0-P:CP %IFMGR-5-ASTATE_UP: Changed uplink state
group Admin state to up: Group 16
Related
Commands
•
show running-config uplink-state-group
– displays the current configuration of one or
more uplink-state groups.
•
show uplink-state-group
– displays the status information on a specified uplink-state
group or all groups.
1584
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...