background image

Delta Networking – Agema Family

AGC7646V1 Aggregation Switch

Installation Guide

agema.deltaww.com 

Содержание AGC764V1

Страница 1: ...Delta Networking Agema Family AGC7646V1 Aggregation Switch Installation Guide agema deltaww com ...

Страница 2: ...licable standard AS NZS CISPR 32 Class A ICES 003 Class A EN55032 Class A VCCI Class A FCC CFR 47 Part 15 Subpart B Class A Safety Applicable standard EN 62368 1 Second Edition UL 62368 1 Second Edition CAN CSA C22 2 No 62368 1 Second Edition IEC 62368 1 Second Edition Including All National Immunity Applicable standard EN 55024 EN 61000 3 2 Harmonic Current Emissions EN 61000 3 3 Voltage Fluctuat...

Страница 3: ...par un cadenas un outil une clé ou par un autre moyen et est contrôlé par l autorité responsable des lieux L accès n est permis que pour le personnel de service ou les utilisateurs qui ont été informés sur les raisons de la restriction imposée sur l emplacement et sur les précautions éventuelles qui doivent être entreprises N ouvrez jamais l équipement et ne mettez pas les modules du bloc d alimen...

Страница 4: ...ent is installed in the restricted access location it should have a separate protective earthing terminal on the chassis which must be permanently connected to earth ground to adequately ground the chassis and protect the operator from electrical hazards This equipment might provide the hazardous voltage and must be connected by qualified service or technical person or be instructed and supervised...

Страница 5: ...cès restreint l équipement doit être doté d une borne de mise à terre distincte sur le châssis qui doit être branchée adéquatement et en permanence afin de le mettre à terre et protéger les utilisateurs contre les dangers électriques Cet équipement peut générer du courant dangereux et doit être branché par du personnel technique ou de service qualifié ou par des personnes informées et supervisées ...

Страница 6: ... 8 2 5 Power Supply Modules 9 2 6 Fan Tray Module 10 Chapter 3 Installation 11 3 1 Mounting 11 3 2 Installing an Optional Transceiver and Cable 14 3 3 Connecting to the Console Port 15 3 4 Connecting to a Power Source 16 Chapter 4 Making the Network Connections 19 4 1 Twisted pair Connections 19 4 2 Fiber Optic Connections 20 4 3 Ethernet Cabling 21 Appendix 1 Technical Specifications 22 Appendix ...

Страница 7: ...yer 2 and layer 3 features including SNMP Spanning Tree VLAN QinQ Trunk QoS RIP OSPF IGMP DVMRP PIM DM PIM SM Access Control etc This product which aims for Data Center and Carrier Networks also supports advance features such as MPLS TRILL PFC VEPA QCN VxLAN and NVGRE to meet Data Center high performance and virtualization requirement 1 2 Package Content After unpacking this switch check the conte...

Страница 8: ...atus LED indication and per port LEDs On board high performance CPU system with large memory Hot swappable PSUs and 1 1 redundancy support Hot swappable FANs and 3 1 redundancy support Standard 1RU chassis high 800Gbps interface bandwidth Low pin to pin latency Cut Through and Store Forward Mode 4GB GDDR5 of packet buffer memory External TCAM for extending classification database Support Jumbo Fra...

Страница 9: ...rt x 6 SFP port x 46 Figure 2 1 Front View 2 1 2 Rear View PSU x 1 4 Fan tray slots Secondary PSU slot x 1 optional Figure 2 2 Rear View NOTE The switch supports up to two PSUs However it might be shipped with one power supply pre installed in the rear panel of the switch You may purchase an additional PSU for redundancy ...

Страница 10: ...eration Blinking Green Booting progress or System in diagnostic mode Solid Amber System failure Off No power Power LED Solid Green Power supply units are supplied to the switch operating normally Solid Amber Power supply unit failure Off Power is disconnected Fan LED Solid Green All fans are operating normally Solid Amber One or more fans failure 10G SFP slots LED Solid Lighting Linkup Blinking Ac...

Страница 11: ...hting Linkup Blinking Activity Solid Blue 25G Operation Solid Purple 10G Operation Off No Link LED4 Solid Lighting Linkup Blinking Activity Solid Blue 25G Operation Solid Purple 10G Operation Off No Link LED2 to LED4 support through breakout cable Management port Link LED Off No link is established on the port Solid Yellow A valid link at 10 100Mbps is established on the port Solid Green A valid l...

Страница 12: ...ly LED Figure 2 4 Rear LED Identification LED Description Fan tray LED Solid Green FAN is operating normally Solid Red Fan failure Power Supply LED Solid Green PSU is operating normally Solid Red Unplugged or power lost with a second PSU in parallel still with input power ...

Страница 13: ...Bytes 148 000 000 pps 100GbE 59 520 000 pps 40GbE 14 880 000 pps 10GbE Memory type 4GB GDDR5 of packet buffer memory External TCAM for extending classification database Console port Serial RS232 console ports RJ45 Management port 10 100 1000Mbps auto sensing auto negotiation Port requirements Speed Capability per Port 1G 10Gbps SFP port 40G 100Gbps QSFP28 port 10G 25G QSFP28 port working in breako...

Страница 14: ... Fabric Data Center VPN MPLS VPN MPLS VPN MPLS Data Center Internet Internet Figure 2 5 Data Center Spine and Leaf Deployment BBU BBU BBU Mobile Access Network AGC7646V1 Access Switch 10GbE 10GbE 10 GbE Service Provider Core Access Packet Switch Network AGC7646V1 Aggrega on Switch Provide Edge Router Provide Edge Router AGC7646V1 Aggrega on Switch Figure 2 6 Mobile Access Network Deployment ...

Страница 15: ...ont to back airflow direction Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Remove the power cable from the module prior to removing the module itself Power cable must not be connected prior to insertion in the chassis or equivalent AVERTISSEMENT Le commutateur comporte des modules de bloc d alimentation enfichable et de casse...

Страница 16: ...ule The fan tray module is part of the switch air cooling system that provides cooling for the switch You must install the fan tray module in the switch that matches the airflow direction of the installed power supply unit Figure 2 8 Fan Tray Module ...

Страница 17: ...pment should be properly grounded Particular attention should be given to supply connections other than direct connections to the mains To rack mount devices with sliding rail 1 Install the front mounting bracket to the device using the six M3 screws provided in the rack mounting kit Figure 3 1 Installing the Front Mounting Bracket 2 Pull the inner rail out until it is fully extended and then push...

Страница 18: ... rail back into the outer rail Then repeat the similar step to assemble another middle rail into the outer rail 5 Making sure the L shaped of the rear bracket is facing inward align and push the rail firmly into the rear rack until it clicks into place Then pull the latch of the front bracket and align the hooks with the front rack holes Release the latch to lock the hooks into place NOTE Repeat t...

Страница 19: ...ils and push the switch all the way to the rear of the rack CAUTION Due to the switch s weight it should be installed by at least two people MISE EN GARDE À cause du poids du commutateur au moins deux personnes doivent l installer Figure 3 5 Installing the Front Mounting Bracket 7 If installing a single switch only go to Connecting to a Power Source 8 If installing multiple switches mount them in ...

Страница 20: ...to 4x25G DAC 40G BASE SR 40G BASE LR4 40G AOC Active Optical Cable 40 DAC Direct Attached Cable Figure 3 6 Inserting an SFP Transceiver into a Slot Figure 3 7 Inserting a QSFP28 or QSFP Transceiver into a Slot To install the SFP QSFP or QSFP28 transceiver follow these steps 1 Consider network and cabling requirements to select an appropriate SFP QSFP or QSFP28 transceiver type 2 Insert the transce...

Страница 21: ...before removing a transceiver SFP QSFP or QSFP28 transceivers are not provided in the switch package 3 3 Connecting to the Console Port This port is used to connect a console device to the switch through a nullmodem serial cable The console device can be a PC or workstation running a VT 100 terminal emulator or a VT 100 terminal NOTE An RJ 45 to DB 9 cable is not supplied with the switch for conne...

Страница 22: ...grounded 3 pin AC power source NOTE For International use you may need to change the AC line cord You must use a line cord set that has been approved for the socket type in your country 3 Check the PSU and front panel LEDs as the device is powered on to be sure that AC power is being received and the Power LED is on If not check that the power cable is correctly plugged in 4 Repeat steps 1 and 2 w...

Страница 23: ...rated 48 60Vdc 20A minimum Tma 45 degree C and the altitude of operation 3048 m The power cable should be 14AWG 20A minimum 48V minimum CAUTION Reversing polarity when connecting DC power wires can permanently damage the power supply or the system Always disconnect the power cable from power source before you service the power supply slots MISE EN GARDE L inversion de la polarité des câbles d alim...

Страница 24: ...ee C and the altitude of operation 3048 m The power cable should be 14AWG 20A minimum 48V minimum CAUTION Reversing polarity when connecting DC power wires can permanently damage the power supply or the system Always disconnect the power cable from power source before you service the power supply slots MISE EN GARDE L inversion de la polarité des câbles d alimentation CC lors de leur branchement p...

Страница 25: ...3 or better for 10BASE T connections 4 1 1 Cabling Guidelines The RJ 45 port on the switch supports an automatic MDI MDI X pinout configuration so you can use a standard straight through twisted pair cable to connect to any other network device PCs servers switches routers or hubs 4 1 2 Connecting to the Management Port 1 Attach one end of a twisted pair cable segment to the link device s RJ 45 co...

Страница 26: ...imum operational temperature of the product You must also use an approved Laser Class 1 SFP or QSFP28 transceiver AVERTISSEMENT Ce commutateur utilise du laser pour émettre des signaux à travers le câble de fibre optique Le laser est conforme aux exigences des produits de laser de classe 1 et par conséquent il est sécuritaire pour les yeux dans des conditions normales de fonctionnement Toutefois v...

Страница 27: ...ainst the current installation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 5e or 6 for 1000BASE T Protection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires switch related or other and elect...

Страница 28: ...IEEE 802 3x Flow Control IEEE 802 3z 1000BASE X IEEE 802 3ae 10Gb s Ethernet IEEE 802 3ba 40Gb s Ethernet Interface Information Interface Small Form factor Pluggable Plus SFP slot x 46 Quad Small Form factor Pluggable 28 QSFP28 slot x 6 10 100 1000Mbps console Management port x 1 External Console port RJ45 x 1 USB port x 1 Power Supply Unit Type AC in PSU DC in PSU Max output power 850W 800W Input...

Страница 29: ... manufacturers to perform repairs and or to build replacement products All replaced or repaired products will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer Unless otherwise having a separate service level agreement SLA with Delta you may only have any in warranty product returned to Delta for repair or replacement in a normal turnaround time w...

Страница 30: ...nty defective product return you shall be responsible for proper packaging and Delta will not take responsibility for any shipping damage due to your improper product packaging Disclaimer EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH IN THIS LIMITED AND SUPPORT WARRANTY DELTA MAKES NO OTHER WARRANTIES REGARDING THE PRODUCT ANY PARTS INCORPORATED THEREIN OR ANY SERVICES PROVIDED THEREWITH AND HEREB...

Страница 31: ......

Отзывы: