vlan
vlan-range
Enter the keyword
vlan
followed by the VLAN number(s). The range
is 1 to 4094.
cost
number
Enter the keyword
cost
followed by the port cost value. The range is
1 to 200000.
Defaults:
•
100 Mb/s Ethernet interface = 200000.
•
1-Gigabit Ethernet interface = 20000.
•
10-Gigabit Ethernet interface = 2000.
•
Port Channel interface with one 100 Mb/s Ethernet = 200000.
•
Port Channel interface with one 1-Gigabit Ethernet = 20000.
•
Port Channel interface with one 10-Gigabit Ethernet = 2000.
•
Port Channel with two 1-Gigabit Ethernet = 18000.
•
Port Channel with two 10-Gigabit Ethernet = 1800.
•
Port Channel with two 100-Mbps Ethernet = 180000.
priority
value
Enter the keyword
priority
followed the Port priority value in
increments of 16. The range is 0 to 240. The default is 128.
loopguard
(C-, S-, and E-Series TeraScale only) Enter the keyword
loopguard
to enable loop guard on a PVST+ port or port-channel interface.
rootguard
(C-, S-, and E-Series TeraScale only) Enter the keyword
rootguard
to enable root guard on a PVST+ port or port-channel interface.
Defaults
Not configured.
Command Modes
INTERFACE
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.4.2.1
Introduced the
loopguard
and
rootguard
options on the E-
Series TeraScale, C-Series, and S-Series.
Version 8.3.7.0
Introduced on the S4810.
Version 8.2.1.0
Introduced the hardware
shutdown-on-violation
option.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
Version 7.4.1.0
Added the optional Bridge Port Data Unit (BPDU) guard.
Version 6.2.1.1
Introduced.
Usage
Information
The BPDU guard option prevents the port from participating in an active STP topology in case a
BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This
option places the port into an the Error Disable state if a BPDU appears, and a message is
logged so that the administrator can take corrective action.
1294
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...