Version 8.3.7.0
Introduced on the S4810.
Version 7.5.1.0
Introduced on the E-Series.
Usage
Information
FTOS counts the SA messages originated by itself and those received from the MSDP peers.
When the total SA messages reach this limit, the subsequent SA messages are dropped (even
if they pass RPF checking and policy checking).
If the total number of SA messages is already larger than the limit when this command is
applied, those SA messages that are already in FTOS continue to be accepted. To enforce the
limit in such situation, use the
clear ip msdp sa-cache
command.
Related
Commands
ip msdp peer
– configures the MSDP peer.
clear ip msdp peer
– clears the MSDP peer.
show ip msdp
– displays the MSDP information
ip msdp shutdown
Administratively shut down a configured MSDP peer.
E-Series, Z-Series, S4810
Syntax
ip msdp shutdown {
peer address
}
Parameters
peer address
Enter the peer address in a dotted decimal format (A.B.C.D.).
Defaults
Not configured.
Command Modes
CONFIGURATION
Command History
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 6.2.1.1
Introduced
ip multicast-msdp
Enable MSDP.
E-Series, Z-Series, S4810
Syntax
ip multicast-msdp
To exit MSDP, use the
no ip multicast-msdp
command.
1096
Содержание Force10 S4810P
Страница 1: ...FTOS Command Line Reference Guide for the S4810 System FTOS 9 1 0 0 ...
Страница 48: ...48 ...
Страница 62: ...62 ...
Страница 92: ...92 ...
Страница 102: ...102 ...
Страница 202: ...202 ...
Страница 216: ...216 ...
Страница 334: ...334 ...
Страница 564: ...564 ...
Страница 570: ...570 ...
Страница 594: ...594 ...
Страница 632: ...632 ...
Страница 642: ...642 ...
Страница 662: ...662 ...
Страница 670: ...Related Commands clear ip dhcp snooping clears the contents of the DHCP binding table 670 ...
Страница 688: ...688 ...
Страница 702: ...702 ...
Страница 712: ...712 ...
Страница 723: ...Related Commands show gvrp displays the GVRP configuration 723 ...
Страница 724: ...724 ...
Страница 736: ...736 ...
Страница 900: ...900 ...
Страница 934: ...934 ...
Страница 958: ...958 ...
Страница 966: ...966 ...
Страница 1018: ...1018 ...
Страница 1026: ...1026 ...
Страница 1086: ...1086 ...
Страница 1100: ...1100 ...
Страница 1116: ...1116 ...
Страница 1164: ...1164 ...
Страница 1268: ...1268 ...
Страница 1276: ...1276 ...
Страница 1286: ...1286 ...
Страница 1300: ...1300 ...
Страница 1376: ...1376 ...
Страница 1390: ...1390 ...
Страница 1460: ...1460 ...
Страница 1512: ...1512 ...
Страница 1518: ...1518 ...
Страница 1528: ...1528 ...
Страница 1538: ...1538 ...
Страница 1551: ...To display the type of STP guard Portfast BPDU root or loop guard enabled on a port enter the show spanning tree 0 command 1551 ...
Страница 1552: ...1552 ...
Страница 1572: ...1572 ...
Страница 1586: ... uplink state group creates an uplink state group and enables the tracking of upstream links 1586 ...
Страница 1598: ...FTOS config interface vlan 40 FTOS conf if vlan tagged TenGi 8 0 FTOS conf if vlan exit FTOS config 1598 ...
Страница 1612: ...1612 ...