PRELIMINARY
DISPLAY CONTROLLER
S3C6400X RISC MICROPROCESSOR
14-20
Preliminary product information describe products that are in development,
for which full characterization data and associated errata are not yet available.
Specifications and information herein are subject to change without notice.
WinOut(R) = Win0123(R) x
Beta
+ Win4(R) x
Alpha
WinOut(G) = Win0123(G) x
Beta
+ Win4(G) x
Alpha
WinOut(B) = Win0123(B) x
Beta
+ Win4(B) x
Alpha
Where,
if A bit is set then
AR1 = Window 1’s Red blending factor (ALPHA1_R@VIDOSD1C)
AR2 = Window 2’s Red blending factor (ALPHA1_R@VIDOSD2C)
AR3 = Window 3’s Red blending factor (ALPHA1_R@VIDOSD3C),….
Else if A bit is cleared then
AR1 = Window 1’s Red blending factor (ALPHA0_R@VIDOSD1C)
AR2 = Window 2’s Red blending factor (ALPHA0_R@VIDOSD2C)
AR3 = Window 3’s Red blending factor (ALPHA0_R@VIDOSD3C),….
In case Win01(R), Alpha and Beta value is determined by
Alpha
= AR1/16,
Beta
= (15-AR1)/16
if AR1 == 0xF then
Alpha
=1 and
Beta
=0
if AR1 == 0x0 then
Alpha
=0 and
Beta
=1