PRELIMINARY
GPIO
S3C6400 RISC MICROPROCESSOR
10-
58
Preliminary product information describe products that are in development,
for which full characterization data and associated errata are not yet available.
Specifications and information herein are subject to change without notice.
EINT0CON1
Bit
Description
Initial State
Reserved [31:23]
Reserved
000000000
EINT27, 26
[22:20]
Setting the signaling method of the EINT27 and EINT26.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
Reserved [19]
Reserved
0
EINT25, 24
[18:16]
Setting the signaling method of the EINT25 and EINT24.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
Reserved [15]
Reserved
0
EINT23, 22
[14:12]
Setting the signaling method of the EINT23 and EINT22.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
Reserved [11]
Reserved
0
EINT21, 20
[10:8]
Setting the signaling method of the EINT21 and EINT20.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
Reserved [7]
Reserved
0
EINT19, 18
[6:4]
Setting the signaling method of the EINT19 and EINT18.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
Reserved [3]
Reserved
0
EINT17, 16
[2:0]
Setting the signaling method of the EINT17 and EINT16.
000 = Low level 001 = High level
01x = Falling edge triggered 10x = Rising edge triggered
11x = Both edge triggered
000
EINT0FLTCON0
Bit
Description
Initial State
FLTEN
[31]
Filter Enable for EINT6, 7
0 = disables
1 = enabled
0
FLTSEL
[30]
Filter Selection for EINT6, 7
0 = delay filter
1 = digital filter(clock count)
0
EINT6, 7
[29:24]
Filtering width of EINT6, 7
This value is valid when FLTSEL is 1.
000
FLTEN
[23]
Filter Enable for EINT4, 5
0 = disables
1 = enabled
0