PRELIMINARY
S3C6400X RISC MICROPROCESSOR
ONENAND CONTROLLER
7-31
Preliminary product information describe products that are in development,
for which full characterization data and associated errata are not yet available.
Specifications and information herein are subject to change without notice.
ERROR BLOCK ADDRESS REGISTER
Register
Address
R/W
Description
Reset Value
ERR_BLK_ADDR0
ERR_BLK_ADDR1
0x701001E0
0x701801E0
R
Bank0 Error Block Address Register
0x0000
ERR_BLK_ADDRn
Bit
Description
Initial State
Reserved [31:12]
0
FAIL_BLK_ADDR [11:0]
After a program, load or erase error interrupt, this register will
hold the block address of the failing operation. Read-Only.
0
FLASH VERSION ID REGISTER
Register
Address
R/W
Description
Reset Value
FLASH_VER_ID0
FLASH_VER_ID1
0x701001F0
0x701801F0
R
Bank0 Flash Version ID Register
Memory
dependent
FLASH_VER_IDn
Bit
Description
Initial State
Reserved [31:16]
FLASH_VER
[15:0]
The value programmed will depend on the actual memory
device being used. The register is set by the flash controller