Goodrive350A series high-performance multifunction VFD
Function parameter list
-279-
Function
code
Name
Description
Default
Modify
P90.14
Roll diameter
calculation delay
time
0.0
–100.0s
1.0s
○
P90.15
Min. roll diameter 0.0mm
–P90.16
50.0mm
○
P90.16
Max. roll diameter P90.15
–5000.0mm
1000.0 mm
○
P90.17
Initial roll diameter
1
P90.15
–P90.16 (mm)
100.0 mm
○
P90.18
Initial roll diameter
2
P90.15
–P90.16 (mm)
100.0 mm
○
P90.19
Initial roll diameter
3
P90.15
–P90.16 (mm)
100.0 mm
○
P90.20
Linear speed roll
diameter
calculation filter
time
0.000
–60.000s
2.000s
○
P90.21
Linear speed roll
diameter
calculation
restriction
0x00
–0x11
Ones place:
0:No
1: Restrict changes in reverse direction
Tens place:
0: No
1: Automatic restriction according to running
frequency and material thickness
0x00
○
P90.22
Material thickness 0.001
–65.535mm
0.010 mm
○
P90.23
Number of coils per
layer
1
–10000
1
◎
P90.24
Revolution counting
function selection
0
–2
0: Digital terminal input
1: PG card input
(Applicable to thickness calculation method)
2: Running frequency
(No input automatic revolution counting)
0
◎
P90.25
Number of pulses
per revolution
1
–60
1
◎
P90.26
Roll diameter set
value
0.0
–100.0%
80.0%
○
P90.27 Roll diameter reset 0x0000
–0x1111
0x1000
○