Goodrive350A series high-performance multifunction VFD
Function parameter list
-262-
Function
code
Name
Description
Default
value
Modify
1: Filter
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode
0: Self-adaptive filter
1: Use P24.19 filter parameters
Bit6: Frequency- division output source
setting (valid only for incremental encoders)
0: Encoder signals
1: Pulse reference signals
Bits 7
–15: Reserved
P24.08
Enabling Z pulse
offline detection
0x00
–0x11
Ones place: Z pulse
0: Do not detect
1: Enable
Tens place: UVW pulse (for SM)
0: Do not detect
1: Enable
0x10
○
P24.09
Initial angle of Z
pulse
Relative electric angle of encoder Z pulse and
motor pole position.
Setting range: 0.00
–359.99
0.00
○
P24.10
Initial angle of the
pole
Relative electric angle of encoder position and
motor pole position.
Setting range: 0.00
–359.99
0.00
○
P24.11
Autotuning of initial
angle of pole
0
–3
0: No operation
1: Rotary autotuning (DC brake)
2: Static autotuning (suitable for resolver-type
encoder, sin/cos with CD signal feedback)
3: Rotary autotuning (initial angle
identification)
0
◎
P24.12
Speed
measurement
optimization
selection
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
1
◎
P24.13
CD signal zero
0
–65535
0
○