Goodrive350A series high-performance multifunction VFD
Function parameter list
-190-
Function
code
Name
Description
Default
Modify
synchronization (S-Err)
70: EC PT100 detected overheating (OtE1)
71: EC PT1000 detected overheating (OtE2)
72: EtherNet/IP communication timeout
(E-EIP)
73: No upgrade bootload (E-PAO)
74: AI1 disconnected (E-AI1)
75: AI2 disconnected (E-AI2)
76: AI3 disconnected (E-AI3)
P07.33
Running frequency
at present fault
0.00Hz
–P00.03
0.00Hz
●
P07.34
Ramp reference
frequency at
present fault
0.00Hz
–P00.03
0.00Hz
●
P07.35
Output voltage at
present fault
0
–1200V
0V
●
P07.36
Output current at
present fault
0.0
–6300.0A
0.0A
●
P07.37
Bus voltage at
present fault
0.0
–2000.0V
0.0V
●
P07.38
Max. temperature at
present fault
-20.0
–120.0°C
0.0°C
●
P07.39
Input terminal status
at present fault
0x0000
–0xFFFF
0
●
P07.40
Output current
status at present
fault
0x0000
–0xFFFF
0
●
P07.41
Running frequency
at last fault
0.00Hz
–P00.03
0.00Hz
●
P07.42
Ramp reference
frequency at last
fault
0.00Hz
–P00.03
0.00Hz
●
P07.43
Output voltage at
last fault
0
–1200V
0V
●
P07.44
Output current at
last fault
0.0
–6300.0A
0.0A
●
P07.45
Bus voltage at last 0.0
–2000.0V
0.0V
●