Goodrive350A series high-performance multifunction VFD
Function parameter list
-149-
Function
code
Name
Description
Default
Modify
0: Disable
1: Enable. If the restart condition is met, the
VFD will run automatically after waiting the
time defined by P01.22.
P01.22
Wait time for restart
after power-off
The parameter indicates the wait time before
the automatic running of the VFD that is
re-powered on.
Output frequency
Running
Power off
Power on
Running
t
t1
t2
t1=P01.22
t2=P01.23
Setting range: 0.0
–3600.0s (valid when
P01.21=1)
1.0s
○
P01.23
Start delay
After a VFD running command is given, the
VFD is in standby state and restarts with the
delay defined by P01.23 to implement brake
release.
Setting range: 0.0
–600.0s
0.0s
○
P01.24
Stop speed delay 0.0
–600.0s
0.0s
○
P01.25
Open-loop 0Hz
output selection
0: Output without voltage
1: Output with voltage
2: Output with the DC braking current for stop
0
○
P01.26
DEC time for
emergency stop
0.0
–60.0s
2.0s
○
P01.27
Time of ending
segment of DEC S
curve
Time of starting
segment of DEC S
curve
0.0
–50.0s
0.1s
◎
P01.28
Time of ending
segment of DEC S
curve
0.0
–50.0s
0.1s
◎
P01.29
Short-circuit braking
current
When the VFD starts in direct start mode
(P01.00=0), set P01.30 to a non-zero value to
enter short-circuit braking.
0.0%
○
P01.30
Hold time of
0.00s
○