Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-120-
Function
code
Name
Description
Default
PID feedback value -100.0–100.0%
0.0%
5.5.16 Running at wobbling frequency
Wobbling frequency is mainly applied in cases where transverse movement and winding functions are
needed like textile and chemical fiber industries. The typical working process is shown as below.
0
1
2
3
4
5
6
7
8
9
10
11
Keypad
AI1
PROFIBUS/CANopen/DeviceNet
Modbus/Modbus TCP
PID
Multi-step speed
Simple PLC
HDIA
AI3
AI2
Ethernet
Pulse train AB
P00.06
(A frequency command
selection)
Frequency set by keypad
P00.10
P08.15
Amplitude of wobbling frequency
*
*
Maintain current
frequency
Set frequency
P00.11 acceleration time 1
P00.12 deceleration time 1
Wobbling
frequency
output
Terminal function 26
wobbling frequency
pause
Terminal function 27
Wobbling frequency reset
Valid
Invalid
Valid
Invalid
HDIB
EtherCAT/PROFINET/EtherNet IP
Programmable card
12
13
14
Function
code
Name
Description
Default
Max. output frequency P00.03
–400.00Hz
50.00Hz
Setting channel of A
frequency command
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDIA
5: Simple PLC program
6: Multi-step speed running
7: PID control
8: Modbus/Modbus TCP communication
9: PROFIBUS/CANopen/DeviceNet
communication
10: Ethernet communication
11: High-speed pulse HDIB
12: Pulse train AB
13: EtherCAT/PROFINET/EtherNet IP
communication
14: Programmable card
0