Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-56-
Function
code
Name
Description
Default
Note:
For these settings, 100% corresponds to the
motor rated current.
Setting source
of braking
torque upper
limit
0: Keypad (set by P03.21)
1
–10: Same as those for P03.18
0
Electromotive
torque upper
limit
set through
keypad
0.0
–300.0% (of the motor rated current)
180.0%
Braking
torque upper
limit set
through
keypad
180.0%
Weakening
coefficient in
constant
power zone
0.1
–2.0
0.3
Lowest
weakening
point in
constant
power zone
10%
–100%
20%
Max. voltage
limit
0.0
–120.0%
100.0%
Pre-exciting
time
0.000
–10.000s
0.300s
Enabling
torque control
0: Disable
1: Enable
0
P03.33
Flux
weakening
integral gain
0
–8000
1200
Control
optimization
setting
0
–0x1111
Ones place: Torque command selection
0: Torque reference
0x0000