Goodrive350A series high-performance multifunction VFD
Function parameter list
-252-
Function
code
Name
Description
Default
value
Modify
feedforward gain For pulse train reference only (position
control)
P21.14
Position
feedforward filter
time constant
0.0
–3200.0ms
For pulse train reference only (position
control)
3.0ms
○
P21.15
Position command
filter time constant
The position feedforward filter time constant
during pulse train positioning.
0.0
–3200.0ms
0.0ms
◎
P21.16
Digital positioning
mode
0x0000
–0xFFFF
Bit0: Positioning mode selection
0: Relative position
1: Absolute position (home) (reserved)
Bit1: Positioning cycle selection
0: Cyclic positioning by terminals
1: Automatic cyclic positioning
Bit2: Cycle mode
0: Continuous
1: Repetitive (supported by automatic cyclic
positioning only)
Bit3: P21.17 digital setting mode
0: Incremental
1: Position type (do not support continuous
mode)
Bit4: Home searching mode
0: Search for the home just once
1: Search for the home during each run
Bit5: Home calibration mode
0: Calibrate in real time
1: Single calibration
Bit6: Positioning completion signal selection
0: Valid during the time set by P21.25 (Hold
time of positioning completion signal)
1: Always valid
Bit7: Initial positioning selection (for cyclic
positioning by terminals)
0: Invalid (do not rotate)
1: Valid
Bit8: Positioning enable signal selection (for
0x0000
○