Goodrive350A series high-performance multifunction VFD
Function parameter list
-147-
Function
code
Name
Description
Default
Modify
deadzone time
time specified in P01.14 during FWD/REV
rotation switching. See the figure.
Output frequency f
Forward
Reverse
Deadzone
time
Time t
Starting
frequency
Switch over after
zero frequency
Switch over after
starting frequency
Setting range: 0.0
–3600.0s
P01.14
FWD/REV running
switching mode
0: Switch at zero frequency
1: Switch at the starting frequency
2: Switch after the speed reaches the stop
speed with a delay
0
◎
P01.15
Stop speed
0.00
–100.00Hz
0.50Hz
◎
P01.16
Stop speed
detection mode
0: Detect by the set speed (unique in space
voltage vector control mode)
1: Detect by the feedback speed
0
◎
P01.17
Stop speed
detection time
0.00
–100.00s
0.50s
◎
P01.18
Terminal-based
running command
protection at
power-on
When the channel of running commands is
terminal control, the system detects the state
of the running terminal during power-on.
0: The terminal running command is invalid at
power-on. Even the running command is
considered as valid during power-on, the VFD
does not run and it keeps the protection state
until the running command is canceled and
enabled again.
1: The terminal running command is valid at
power-on. If the running command is
considered as valid during power-on, the VFD
is started automatically after the initialization.
Note:
Exercise caution before using this
function. Otherwise, serious result may follow.
0
○
P01.19
Action selected
when running
frequency less than
This parameter specifies the running status of
VFD when the set frequency is below the
0x00
◎