Goodrive350A series high-performance multifunction VFD
Function parameter list
-256-
Function
code
Name
Description
Default
value
Modify
Bit4: Positioning mode selection 1
0: Set direction positioning
1: Near-by direction positioning
Bit5: Positioning mode selection 2
0: Forward positioning
1: Reverse positioning
Bit6: Zeroing command selection
0: Electric level mode
1: Pulse mode
Bit7: Reference point calibration mode
0: Calibrate at the first time
1: Calibrate in real time
Bit8: Action selection after zeroing signal
cancellation (electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electric level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bits 11
–15: Reserved
P22.01
Speed of spindle
orientation
During spindle orientation, the speed of the
position point of orientation will be searched,
and then it will switch over to position control
orientation.
Setting range: 0.00
–100.00Hz
10.00Hz
○
P22.02
DEC time of spindle
orientation
DEC time of spindle orientation.
Spindle orientation DEC time means the time
needed for the VFD to decelerate from Max.
output frequency (P00.03) to 0Hz.
Setting range: 0.0
–100.0s
3.0s
○
P22.03
Spindle zeroing
position 0
You can select the zeroing positions of four
spindles by terminals (function code 46, 47).
Setting range: 0
–65535
0
○
P22.04
Spindle zeroing
position 1
Setting range: 0
–65535
0
○