Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-100-
Setting
Function
Description
84
–95
Reserved
/
Related parameter list:
Function
code
Name
Description
Default
HDI input type
0x00
–0x11
Ones: HDIA input type
0: HDIA is high-speed pulse input
1: HDIA is digital input
Tens: HDIB input type
0: HDIB is high-speed pulse input
1: HDIB is digital input
0x00
Function of S1 terminal 0: No function
1: Forward running
2: Reverse running
3: 3-wire control/Sin
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease
setting
13: Switchover between setup A and setup
B
14: Switchover between combination setting
and A setting
15: Switchover between combination setting
and setup B
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: Acceleration/deceleration time selection
1
Function of S2 terminal
4
Function of S3 terminal
7
Function of S4 terminal
0
Function of HDIA
terminal
0
Function of HDIB
terminal
0