Goodrive350A series high-performance multifunction VFD
Function parameter list
-270-
Function
code
Name
Description
Default
value
Modify
P26.41
AO2 output
corresponding to
upper limit
different analog outputs.
10V (20mA)
0.0%
100.0%
AO
Setting range of P26.38: -300.0%
Setting range of P26.39: 0.00V
–10.00V
Setting range of P26.40: P26.38
–100.0%
Setting range of P26.41: 0.00V
–10.00V
Setting range of P26.42: 0.000s
–10.000s
Setting range of P26.43: -300.0%
Setting range of P26.44: 0.00V
–10.00V
Setting range of P26.45: P26.43
–300.0%
Setting range of P26.46: 0.00V
–10.00V
Setting range of P26.47: 0.000s
–10.000s
10.00V
○
P26.42
AO2 output filter
time
0.000s
○
P26.43
AO3 output lower
limit
0.0%
○
P26.44
AO3 output
corresponding to
lower limit
0.00V
○
P26.45
AO3 output upper
limit
100.0%
○
P26.46
AO3 output
corresponding to
upper limit
10.00V
○
P26.47
AO3 output filter
time
0.000s
○
P26.48
–
P26.52
Reserved
0
–65535
0
○
P27
—
Programmable expansion card functions
Function
code
Name
Description
Default
value
Modify
P27.00
Enabling
programmable card
0
–1
This function is reserved.
0
◎
P27.01
I_WrP1
0
–65535
Used to write a value to WrP1 of the
programmable card.
0
○
P27.02
I_WrP2
0
–65535
Used to write a value to WrP2 of the
programmable card.
0
○
P27.03
I_WrP3
0
–65535
Used to write a value to WrP3 of the
programmable card.
0
○
P27.04
I_WrP4
0
–65535
Used to write a value to WrP4 of the
programmable card.
0
○