Goodrive350A series high-performance multifunction VFD
Troubleshooting
-303-
7.6.7 Motor stalls during ACC
Motor stalls during
ACC
Whether the ACC
time is too short?
If it is a VFD fault or
interference, contact us
Overcurrent
If it is a VFD fault or
interference, contact
us
Whether parameter
autotuning is
performed?
Modify the torque
boost
Whether the
torque boost
is too high?
过电流
Whether a special
motor is used?
Reduce the inertia of
the load and
increase the capacity
of the VFD
Whether it is V/F
control?
Contact us
Whether the load
torque is too large?
Use larger cables, shorten the
wiring distance, adjust the voltage
drop of the output reactor, etc.
Whether the load
or inertia is too
large?
Increase the ACC
time
Check the voltage of the
terminals of the motor with a
multimeter. Whether the voltage
is within the defined range?
Reduce the torque of
the load and
increase the capacity
of the VFD
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No