Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-42-
The parameters of user defined parameter setting can be added, deleted or adjusted as needed, such
as "Place top", "Move up", "Move down", "Delete from the list", and "Restore default parameters"; the
adding function can be set in a certain function code in a function group. The edit function is shown in
the figure below.
16:02:35
Grouping parameters
State parameter
Motor parameter autotuning
Parameter copy/Restore default
System setting
Fwd
Local
Ready
User defined parameter setting
GD350A
16:02:35
P00.00: Speed Ctrl Run Cmd
P00.02: Comm Cmd Channel
P00.03: Max Output Freq
P00.04: RunFreq Up Limit
P00.05: RunFreq Low Limit
Fwd
Local
Ready
P00.01: Run Cmd Channel
16:02:35
Place top
Fwd
Local
Ready
Move up
Delete from the list
Move down
Restore default parameters
GD350A
GD350A
Back Home Sele
Back Edit Sele
Back Home Sele
Figure 5.12 List edit diagram 3
5.4.3 Adding parameters to the parameter list displayed in stopped/running state
You can choose
Menu
>
State monitoring
,
choose
a submenu, and enter a specific function group
and then a specific function code to add the parameter to the list of parameters displayed in stopped
state or parameters displayed in running state.
GD350A
16:02:35
Stopped-state parameters
Running-state parameters
GD350A
16:02:35
Sure to add to Stopped-state
parameters?
Fwd
Local
Ready
Fwd
Local
Ready
16:02:35
P17.01
:
OutpFreq
P17.00
:
Set Freq
P17.11
:
DC Bus Volt
P17.03
:
Outp Volt
P17.04
:
Outp Cur
P17.05
:
Motor Speed
GD350A
Fwd
Local
Ready
Back Add OK
Back Home Sele
Back Home OK
GD350A
16:02:35
Stopped-state parameters
GD350A
16:02:35
Sure to add to Running-state
parameters?
Fwd
Local
Ready
Fwd
Local
Ready
16:02:35
P17.01
:
OutpFreq
P17.00
:
Set Freq
P17.11
:
DC Bus Volt
P17.03
:
Outp Volt
P17.04
:
Outp Cur
P17.05
:
Motor Speed
GD350A
Fwd
Local
Ready
Back Add OK
Back Home Sele
Back Home OK
Running-state parameters
Figure 5.13 Adding parameter diagram 1
Aftering selecting a specific function code, press
key to enter parameter addition interface,
and press
key,
key or
key to confirm the addition operation. If this parameter is not
included in the list of parameters displayed in stopped state or list of parameters displayed in running
state, the parameter added will be at the end of the list; if the parameter is already in the list of
parameters displayed in stopped state or list of parameters displayed in running state, the addition
operation will be invalid. If
key or
key is pressed without selecting addition operation in
"Addition" interface, it will return to monitoring parameter list menu.
Part of the monitoring parameters in P07 HMI group can be added to the "parameter displayed in stop
state" list or "parameter displayed in running state" list; all the parameters in P17, P18 and P19 group
can be added to the "parameter displayed in stop state" list or "parameter displayed in running state"
list.