Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-97-
Setting
Function
Description
39
Pre-exciting command
When this terminal is valid, motor pre-exciting will be
started until this terminal becomes invalid.
40
Zero out power consumption
quantity
After this command becomes valid, the power
consumption quantity of the VFD will be zeroed out.
41
Maintain power consumption
quantity
When this command is valid, current operation of the
VFD will not impact the power consumption quantity.
42
Source of upper torque limit
switches to keypad
When this command is valid, the upper limit of the torque
will be set by keypad.
43
Position reference point input Valid only for S1, S2, and S3.
44
Disable spindle orientation
Spindle orientation is invalid.
45
Spindle zeroing/local position
zeroing
Spindle positioning is triggered.
46
Spindle zero position selection
1
Spindle zero position selection 1.
47
Spindle zero position selection
2
Spindle zero position selection 2.
48
Spindle scale division
selection 1
Spindle scale division selection 1.
49
Spindle scale division
selection 2
Spindle scale division selection 2.
50
Spindle scale division
selection 3
Spindle scale division selection 3.
51
Position/speed control
switchover terminal
Terminal for switching between position control and
speed control.
52
Disable pulse input
Pulse input is invalid when the terminal is valid.
53
Clear position deviation
Used to clear the input deviation of position loop.
54
Switch position proportional
gains
Used to switch position proportional gains.