Goodrive350A series high-performance multifunction VFD
Function parameter list
-237-
Function
code
Name
Description
Default
value
Modify
P17.24 PID feedback value
Displays PID feedback value
Range: -100.0
–100.0%
0.0%
●
P17.25 Motor power factor
Displays the power factor of current motor.
Range: -1.00
–1.00
1.00
●
P17.26
Time elapsed of this
run
Displays the time elapsed of this run.
Range: 0
–65535min
0min
●
P17.27
Simple PLC and
current step
number of
multi-step speed
Displays simple PLC and current step number
of multi-step speed
Range: 0
–15
0
●
P17.28
Motor ASR
controller output
Displays the speed loop ASR controller output
value under vector control mode, relative to
the percentage of rated torque of the motor.
Range: -300.0%
–300.0% (of the rated motor
current)
0.0%
●
P17.29
Pole angle of
open-loop SM
Displays initial identification angle of SM
Range: 0.0
–360.0
0.0
●
P17.30
Phase
compensation of
SM
Displays phase compensation of SM
Range: -180.0
–180.0
0.0
●
P17.31
High-frequency
superposition
current of SM
0.0%
–200.0% (of the rated motor current)
0.0%
●
P17.32
Motor flux linkage 0.0%
–200.0%
0.0%
●
P17.33
Exciting current
reference
Displays the exciting current reference value
under vector control mode
Range: -3000.0
–3000.0A
0.0A
●
P17.34
Torque current
reference
Displays torque current reference value under
vector control mode
Range: -3000.0
–3000.0A
0.0A
●
P17.35
AC incoming
current
Displays the valid value of incoming current
on AC side
Range: 0.0
–5000.0A
0.0A
●
P17.36
Output torque
Displays output torque value, during forward
running, positive value is motoring state,
negative value is generating state; during
reverse running, positive value is generating
0.0Nm
●