Goodrive350A series high-performance multifunction VFD
Function parameter list
-150-
Function
code
Name
Description
Default
Modify
short-circuit braking
for start
During stop, if the running frequency of VFD
is lower than the starting frequency P01.09 of
brake for stop, set P01.31 to a non-zero value
to enter short-circuit braking for stop, and
then carry out DC braking in the time set by
P01.12. (Refer to the descriptions for
Setting range of P01.29: 0.0
–100.0% (VFD)
Setting range of P01.30: 0.0
–50.00s
Setting range of P01.31: 0.0
–50.00s
P01.31
Hold time of
short-circuit braking
for stop
0.00s
○
P01.32
Pre-exciting time of
jog
0
–10.000s
0.000s
○
P01.33
Starting frequency
of braking for
jogging to stop
0.00Hz
–P00.03
0.00Hz
○
P01.34 Delay to enter sleep 0
–3600.0s
0.0s
○
P02
—
Parameters of motor 1
Function
code
Name
Description
Default
Modify
P02.00
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
◎
P02.01
Rated power of AM
1
0.1
–3000.0kW
Model
depended
◎
P02.02
Rated frequency of
AM 1
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
◎
P02.03
Rated speed of AM
1
1
–60000rpm
Model
depended
◎
P02.04
Rated voltage of AM
1
0
–1200V
Model
depended
◎
P02.05
Rated current of AM
1
0.8
–6000.0A
Model
depended
◎
P02.06
Stator resistance of
AM 1
0.001
–65.535Ω
Model
depended
○
P02.07
Rotor resistance of
AM 1
0.001
–65.535Ω
Model
depended
○
P02.08
Leakage inductance
of AM 1
0.1
–6553.5mH
Model
depended
○